药物信息为Indium In 111 Chloride Sterile Solution (Mallinckrodt Inc.): DESCRIPTION
- DESCRIPTION
- RADIONUCLIDIC PURITY
- RADIOCHEMICAL PURITY
- CHEMICAL PURITY
- PHYSICAL CHARACTERISTICS
- EXTERNAL RADIATION
- CLINICAL PHARMACOLOGY
- INDICATIONS AND USAGE
- CONTRAINDICATIONS
- WARNINGS
- ADVERSE REACTIONS
- DOSAGE AND ADMINISTRATION AND RADIATION DOSIMETRY
- HOW SUPPLIED
- SPECIAL STORAGE AND HANDLING
- 外部链接相关的Indium In 111 Chloride Sterile Solution (Mallinckrodt Inc.)
Indium In 111 Chloride Sterile Solution is indicated for radiolabeling OncoScint CR/OV and ProstaScint preparations used for in vivo diagnostic imaging procedures. It is also indicated for radiolabeling ZevalinTM preparations used for Radioimmunotherapy procedures. It is supplied as a sterile, non-pyrogenic solution of Indium In 111 Chloride in 0.05 molar hydrochloric acid. No carrier has been added to the solution. Each 0.5 milliliter of the solution contains 185 megabequerels (5 millicuries) of indium In 111 chloride at time of calibration (specific activity of >1.85 GBq/μg Indium; >50 mCi/μg Indium at this time of calibration). The solution pH is 1.1 to 1.4.
- Drug Information Provided by National Library of Medicine (NLM).