The pharmacokinetics of ioversol intravascularly administered in normal subjects conform to an open two compartment model with first order elimination (a rapid alpha phase for drug distribution and a slower beta phase for drug elimination). Based on the blood clearance curves for 12 healthy volunteers (6 receiving 50 mL and 6 receiving 150 mL of OPTIRAY 320), the biological half-life was 1.5 hours for both dose levels and there was no evidence of any dose related difference in the rate of elimination.
Ioversol is excreted mainly through the kidneys following intravascular administration. In patients with impaired renal function, the elimination half-life is prolonged. In the absence of renal dysfunction, the mean half-life for urinary excretion following a 50 mL dose was 118 minutes (105 to 156) and following a 150 mL dose was 105 minutes (74 to 141). Greater than 95% of the administered dose was excreted within the first 24 hours, with the peak urine concentration occurring in the first 2 hours after administration. Fecal elimination was negligible. Ioversol does not bind to serum or plasma proteins to any extent and no significant metabolism, deiodination or biotransformation occurs.
OPTIRAY probably crosses the placental barrier in humans by simple diffusion. It is not known to what extent ioversol is excreted in human milk.
Intravascular injection of ioversol opacifies those vessels in the path of the flow of the contrast medium, permitting radiographic visualization of the internal structures until significant hemodilution occurs.
Ioversol may be visualized in the renal parenchyma within 30 to 60 seconds following rapid intravenous injection. Opacification of the calyces and pelves in patients with normal renal function becomes apparent within 1 to 3 minutes, with optimum contrast occurring within 5 to 15 minutes.
Animal studies indicate that ioversol does not cross the blood-brain barrier or cause endothelial damage to any significant extent.
OPTIRAY enhances computed tomographic imaging through augmentation of radiographic efficiency. The degree of density enhancement is directly related to the iodine content in an administered dose; peak iodine blood levels occur immediately following rapid intravenous injection. Blood levels fall rapidly within 5 to 10 minutes and the vascular compartment half-life is approximately 20 minutes. This can be accounted for by the dilution in the vascular and extravascular fluid compartments which causes an initial sharp fall in plasma concentration. Equilibration with the extracellular compartments is reached in about 10 minutes; thereafter, the fall becomes exponential.
The pharmacokinetics of ioversol in both normal and abnormal tissue have been shown to be variable. Contrast enhancement appears to be greatest immediately after bolus administration (15 seconds to 120 seconds). Thus, greatest enhancement may be detected by a series of consecutive two-to-three second scans performed within 30 to 90 seconds after injection (i.e., dynamic computed tomographic imaging). Utilization of a continuous scanning technique (i.e., dynamic CT scanning) may improve enhancement and diagnostic assessment of tumor and other lesions such as abscess, occasionally revealing unsuspected or more extensive disease. For example, a cyst may be distinguished from a vascularized solid lesion when precontrast and enhanced scans are compared; the nonperfused mass shows unchanged x-ray absorption (CT number). A vascularized lesion is characterized by an increase in CT number in the few minutes after a bolus of intravascular contrast agent; it may be malignant, benign, or normal tissue, but would probably not be a cyst, hematoma, or other nonvascular lesion.
Because unenhanced scanning may provide adequate diagnostic information in the individual patient, the decision to employ contrast enhancement, which may be associated with risk and increased radiation exposure, should be based upon a careful evaluation of clinical, other radiological, and unenhanced CT findings.